Damaged extension cord osha
Web3. Don’t use damaged cords. Cords are easily damaged, and often “repaired” with electrical or duct tape. Although a taped cord may still work, using a damaged power cord is a violation of OSHA regulations, and the cord should be discarded. This is one of the most common violations of OSHA extension cords rules – and one of the easiest ... WebPortable equipment must be handled in a manner that will not cause damage. Flexible electric cords connected to equipment may not be used for raising or lowering the …
Damaged extension cord osha
Did you know?
WebSep 27, 2024 · OSHA standards state that flexible cords made up with wires smaller than 12-gauge shall be used only in continuous lengths without splice or tap. A hard service flexible cord that is fabricated from 12-gauge wire or larger may be spliced, but only if the splice retains the insulation, outer sheath properties, and usage characteristics of the ... WebThis paragraph applies to the use of cord- and plug-connected equipment, including flexible cord sets (extension cords). ( 1) Handling. Portable equipment shall be handled in a manner which will not cause damage. Flexible electric cords connected to equipment may not be used for raising or lowering the equipment.
WebForce a plug into an outlet, say, by bending the ground prong. Run an extension cord near water, or use a wet extension cord. Use a cord that feels hot. Drag or drive over a cord. Do anything you were told not to during safety training. The correct use of extension cords is an important to on-the-job electrical safety because if used ... WebAug 23, 2024 · torn, frayed, or exposed wires tangled and/or overcrowded wires loose electrical connections substandard insulation malfunctioning electrical equipment …
WebDec 31, 2013 · Hazards included two repeat safety violations involve using an extension cord instead of the proper fixed wiring and using damaged electrical cords. Additional electrical hazards and the lack of adequate training and safe work procedures to protect workers on or near energized electrical equipment were also identified. Webelectrical tape, right? However, Federal OSHA electrical safety standards actually do not allow us to make a repair to a frayed or damaged electrical cord using electrical tape, nor can we use electrical tape to splice two cords together. Here is an overview of OSHA’s reasoning for not using electrical tape to make
WebWith the wide use of power tools on construction sites, flexible extension cords often are necessary. Because they are exposed, flexible, and unsecured, they are more susceptible to damage than is fixed wiring. …
WebRule 4. Do not secure extension cords to walls or ceilings using metal nails or staples. Metal fasteners can easily damage the relatively soft flexible jacket of the cord. Slight impacts, pinching or bending can damage the cord. Even pulling on the cable can wear through the jacket accidentally. chrysanthemum japanese empirederwent lightfast coloured pencilsWebBecause these cords are often exposed, flexible, and unsecured, they are highly susceptible to damage and misuse that can result in significant hazards. Following … chrysanthemum japaneseWebMay 8, 2024 · Question: Where an extension cord being used in construction has been damaged near the plug end, is it permissible to replace the plug with an approved cord cap made for that type of cord, provided the repair is done by a qualified electrician? chrysanthemum japonense var. ashizurienseWeb4600 Health Sciences Rd. • Irvine, CA 92697 • (949)-824-6200 • www.ehs.uci.edu • [email protected] DO NOT use surge protectors or power strips for extra outlets, as an “ON/OFF” switch, or as an extension cord to reach appliances or equipment. Check indicator on surge protectors periodically to ensure “protected” light is “ON ... chrysanthemum italyWebFeb 11, 2024 · Let’s review the correct way to repair electrical cords. The first obvious step is often overlooked. Unplug the cord and take control of both ends. Splices: Cut back only enough of the outer and inner insulation to make the repair. Keep in mind that the color-coded wires on one side need to be connected to the like-colored wires on the other. derwent living embley road nottinghamWebInspect all extension cords daily for damage and missing g rounding p ongs. Use a Ground Fault Circuit Interrupter to protect against any electrical fault. Keep extension cords away from foot traffic to prevent tripping and co rd damage. The insulation in cords and electrical tools can become damaged. If a live wire touches derwent living chief executive